Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE)

Committee of Testing Laboratories

SEARCH TOOL

 
QUICK ACCESS TO PRODUCT CATEGORIES
 
   

PRODUCT CATEGORY LITE

 

IEC 60238(ed.5)

IEC 60238(ed.6)

IEC 60238(ed.7)

IEC 60238(ed.8)

IEC 60400(ed.4)

IEC 60400(ed.6);am1

IEC 60570(ed.3);am1;am2

IEC 60570(ed.4)

IEC 60598-1(ed.3)

IEC 60598-1(ed.4)

IEC 60598-1(ed.5)

IEC 60598-1(ed.6)

IEC 60598-2-1(ed.1);am1

IEC 60598-2-2(ed.2);am1

IEC 60598-2-3(ed.3)

IEC 60598-2-4(ed.2)

IEC 60598-2-5(ed.2)

IEC 60598-2-6(ed.2)

IEC 60598-2-7(ed.1);am1;am2

IEC 60598-2-8(ed.1)

IEC 60598-2-8(ed.2)

IEC 60598-2-10(ed.1);am1;am2

IEC 60598-2-10(ed.2)

IEC 60598-2-12(ed.1)

IEC 60598-2-13(ed.1)

IEC 60598-2-20(ed.2);am1;am2

IEC 60598-2-22(ed.3);am1

IEC 60838(ed.1)

IEC 60838(ed.4)

IEC 60921 all editions

IEC 60923 all editions

IEC 60927(ed.2);am1

IEC 60929(ed.1)

IEC 60929(ed.2)

IEC 60968(ed.1);am1;am2

IEC 60969(ed.1);am1;am2

IEC 61047(ed.1);am1

IEC 60147(ed.2)

IEC 61048 (ed.1);am1;am2

IEC 61049(ed.1)

IEC 61184(ed.1)

IEC 61184(ed.2)

IEC 61347 Series

IEC 61347 Series except Parts 2-2, 2-8 and 2-9

IEC 61347-1(ed.1);am1

IEC 61347-2-2(ed.1)

IEC 61347-2-7(ed.1)

IEC 61347-2-8(ed.1)

IEC 61347-2-9(ed.1);am1

IEC 61347-2-11(ed.1)

IEC 61347-2-13(ed.1)

 

CTL DECISION SHEETS

 

IEC 60238(ed.5)

Clause

Subject

Keywords

Sheet

---

Edition of the gauge sheet, when testing lampholder

- gauge
- lampholder

258.CTL-ETF5

IEC 60238(ed.6)

Clause

Subject

Keywords

Sheet

4.9.2

Lampholder to be built into ovens

- oven

268.CTL-ETF5

IEC 60238(ed.7)

Clause

Subject

Keywords

Sheet

8.5

M11x1 threaded entry

- National Mark
- STR
- Threaded entry

209

Figures 17 & 19

Protection against ingress of water

- Drops of liquid
- Holes of equipment
- Ingress of water

398.CTL-ETF5

IEC 60238(ed.8)

Clause

Subject

Keywords

Sheet

General

Gauges

- Gauge
- Test Report
- IEC 60061

554/06

General

Lampholder to be built into oven

- IEC 60238
- Ovens
- IEC 60335-2-6

555/06

1

General

- Adapter
- E14 / E27
- Scope

599/07

8-9

Dimensions and protection against electric shock

- Gauges
- 7006-30 / 7006-31
- Figure 11

600/07

12.1

Test method for checking with "feeler gauge"

- Feeler gauge
- Circular direction
- Lamp caps

556/06

IEC 60400(ed.4)

Clause

Subject

Keywords

Sheet

General

Gauges

- Gauge
- Test Report
- IEC 60061

207

---

Edition of the gauge sheet, when testing lampholder

- gauge
- lampholder

258.CTL-ETF5

IEC 60400(ed.6);am1;am2

Clause

Subject

Keywords

Sheet

General

Gauges

- Gauge
- Test Report
- IEC 60061

554/06

2.3

Push-on lampholders

- Push-on lampholder
- New lamps
- Live parts

124/06

8.2.1
8.2
Standard Sheet 7005-56-2

G10q - connector's construction

- G10q lampholder
- Connector's construction
- Protection against electric shock

091/06.m
Figure 1
Figure 2
Figure 3

17.5

Fire resistance of material retaining live parts in position

- Integrated lampholders
- Fire resistance
- PCBs

PDSH 707

IEC 60570(ed.3);am1;am2

Clause

Subject

Keywords

Sheet

General

Connector with a flexible cord and a normal plus

- Connector
- Flexible cord
- Contacts

203

1

Luminaires with socket outlet connected to track system

- Socket-Outlet
- luminaires
- Track system

204

2.3.3.9 / 5.13

IP 40 indication

- Common conclusion
-
IP 40 indication
- L.I.P

205

IEC 60570(ed.4)

Clause

Subject

Keywords

Sheet

General 1.7

Fixed luminaire with track

- IEC 60570
- 6,5 mm
- Track system

004/06
Figures

General

Opening for the adapters

- Construction
- Openings
- Adapter

557/06

12

Extra safety circuit equivalent to SELV or double/reinforced insulation.

- SELV condition
- Electronic means
- IEC 60364-4-41
  IEC 61140

558/06

IEC 60598-1(ed.3);am1

Clause

Subject

Keywords

Sheet

General

LED's used as a light source in luminaire

- LEDs
- Harmful radiation
- Light intensity

003/06

General

IEC 62262 / EN 50102

- IEC 62262 EN 50102
- IK Code
- Degrees of protection

002/06

General Section 12

Luminaires provided with LEDs

- Control gears
- Section 12
- IEC/EN 60825-1

005/05

0.2

- Socket-outlet mounted rechargeable luminaire
- Rechargeable lamps luminaire

- Socket outlet
- Transformer/Plug
- Battery chargers

007/06

0.5

Completion of Test Report Formats (TRF's) and use of Annex 1 Table of components

- Components
- Certificaation
- TRFs

017/06

3

Marking of lamp types according to IEC TS 61231

- ILCOS codes
- IEC TS
- Test Reports

019/06

3.2.8

Lamp-type information marking

- Manufacturer
- Marking plate
- Instructions

026/06

Annex C

Luminaires for M. H lamps

- Rectifying effect
- Declaration
- Certification Body
- Updated Table

126/06
Table.rect.effect.zip

IEC 60598-1(ed.4)

Clause

Subject

Keywords

Sheet

General

Luminaires system for 230V.

- Luminaires system
- Extra low voltage
- IEC 60598-2-23

002

General

LEDs used as a light source in luminaires

- LEDs
- Harmful radiation
- Light intensity

003/06

General

IEC 62262/ EN 50102

- IEC 62262
EN 50102
-IK code
- Degrees of protection

002/06

General Section 12

Luminaires provided with LEDs

- Control gears
- Section 12
- IEC/EN 60825-1

DSH 005/06

0.2

- Socket-outlet mounted
  rechargeable luminaire
- Rechargeable lamps
  luminaire

- Socket outlet
- Transformer/Plug
- Battery chargers

DSH 007/06

0.5

Completion of Test Report Formats (TRF's) and use of Annex 1Table of components

- Comonents
- Certification
- TRF

017/06

3

Marking of lamp types according to IEC TS 61231

- ILCOS codes
- IEC TS
- Test Reports

019/06

3.2.8

Lamp-type information marking

- Manufacturer
- Marking plate
- Instructions

026/06

4.7.3

Lampholder terminals

- Screwless terminal
- Rewirable luminaire
- Solid/flexible conductors

DSH 036/06

11.2.1

Pendant luminaire with a
"ceiling cone"

- Mounting surface
- Supply wires
- Ceiling cone

120

Annex C

Luminaires for M.H
lamps

- Rectifying effect
- Declaration
- Certification Body
- Updated Table

126/06
Table.rect.effect.zip

Clause

Subject

Keywords

Sheet

Clause

Subject

Keywords

Sheet

IEC 60598-2-1(ed.1);am1

Clause

Subject

Keywords

Sheet

General

Applicable standard 

- Standard
- IEC 60598-2-5
- IEC 60598-2-1

510/06

IEC 60598-2-2(ed.2);am1

Clause

Subject

Keywords

Sheet

2.11

Built in components accessibility

- 50 mm test sphere
- IEC 60598-1
- Built in components
- Accessible part
- 34D/784/CD-Proposal "S"

088/06

2.11

IP protection of recessed parts

- Paragraph 8
- IP classifications
- Item 12.3

501/06

2.11

Consideration relevant built-in components

- Built-in components
- Outside of the luminaire
- Fixed wiring

502/06
Figures

2.11

Luminaire with R7s/RX7s lamp cap

- Lampholder
- Connecting device
- Recessed luminaire

503/06

Annex D

Test recesses in a luminaire with separate parts

- Manufacturer instructions
- Separating distances
- Spacers

504/06

IEC 60598-2-3(ed.3)

Clause

Subject

Keywords

Sheet

3.6.3

Wind force test

- Complete luminaire
- Two fixing devices
- Risk of falling

505/06

3.6.3.1

Wind force test

- Weight
- Wind force test
- Top of the mast

506/06

IEC 60598-2-4(ed.2)

Clause

Subject

Keywords

Sheet

Definitions

Portable lumjnaires, garden luminaires and lighting chains

- Relevant standards
- Ordinary luminaire
- IP classification

508/06

General

Christmas decoration light

- IEC 60598-2-4
- IEC 60598-2-20
- Relevant Clauses

507/06
Figure

General

Scope of application

- Scope of application
- Children
- IEC/EN 60598-2-10
- IEC/EN 60598-2-4

519/06

4.6.3

Stability test

- Stability test
- Portable luminaire
- Salver / Table

596/07

4.12

Floor Luminaire with R7s halogen lamp

- Lighted Objects
- Abnormal Conditions
- Mounting Surface

509/06

4.12.4

Portable luminaire;
different parts can be loosen by hand

- Middle pipe
- Adequate means
- Clause 4.12.4

051/06

IEC 60598-2-5(ed.2)

Clause

Subject

Keywords

Sheet

General

Applicable standard

- Standard
- IEC 60598-2-5
- IEC 60598-2-1

510/06

5.6.5.1

Wind force Test

- Weight
- Wind Force test
- Top of the Mast

506/06

IEC 60598-2-6(ed.2);am1

Clause

Subject

Keywords

Sheet

General

Applicablility of IEC 60598-2-6

- IEC 60598-2-6
- Transformer
- Converter

512/06

General

Transformers to be used

- Basic insulation
- SELV transformers
- Supplementary insulation

513/06

General Section 12

Luminaires provided with LEDs

- Control gears
- Section 12
- IEC/EN 60825-1

005/07

12.5.1a)4)

Requirements for
convertors

- Transformers
- Convertors
- Requirements

118/06

IEC 60598-2-7(ed.1);am1;am2

Clause

Subject

Keywords

Sheet

Definitions

Portable luminaires, garden luminaires and lighting chains

- Relevant standards
- Ordinary luminaire
- IP classification

508/06

7.13

IP classification for portable pedestal luminaires

- IP classification
- Cable entry
- Garden luminaire

514/06
Figure

IEC 60598-2-8(ed.1)

Clause

Subject

Keywords

Sheet

8.10

IP 55 handlamp

- IP classification
- Plug
- IP 44

160

IEC 60598-2-8(ed.2)

Clause

Subject

Keywords

Sheet

8.6.6.1

Mechanical strength for handlamps

- Suspension hook
- Grid or guard (translucent cover)
- 250 N pull

515/06

8.10
5.2.14 (Am1)

IP 55 handlamp

- IP classification
- Plug
- IP 44

516/06